Brockway Dimensions Heathers 50 (1.56 TOG) with Duralay Technics 6 (0.66 TOG) gives a combined 1.22 in-situ TOG. Whether that passes the 2.5 TOG underfloor heating limit and what to do.
Updated 05 September 2026.
Brockway Dimensions Heathers 50 and Duralay Technics 6: combined TOG for underfloor heating
The combined TOG for Brockway Dimensions Heathers 50 over Duralay Technics 6, worked against the UHMA underfloor heating rule.
Combined against the UHMA 2.5 TOG underfloor-heating limit. Under 1.5 also suits a low-temperature heat pump.
| Carpet | Brockway Dimensions Heathers 50 (1.56 TOG) |
|---|---|
| Underlay | Duralay Technics 6 (0.66 TOG) |
| Published sum | 2.22 TOG |
| UHMA in-situ correction | minus 1 TOG |
| Combined in-situ TOG | 1.22 TOG |
| Standard UFH limit | 2.5 TOG |
| Heat pump target | under 1.5 TOG |
Brockway Dimensions Heathers 50 is rated 1.56 TOG and Duralay Technics 6 is rated 0.66 TOG. Laid together the combination is what the underfloor heating has to warm through.
The published TOG figures add to 2.22. The UHMA rule subtracts 1 TOG because tests showed real in-situ resistance runs about a TOG below the paper sum, giving 1.22 TOG. That clears both the standard limit and the tighter heat-pump target.
Questions and answers
Brockway Dimensions Heathers 50 and Duralay Technics 6: combined TOG for underfloor heating?
Combined in-situ TOG is 1.22, under the 2.5 TOG limit, so Brockway Dimensions Heathers 50 with Duralay Technics 6 is suitable for a standard underfloor heating system. It is also under 1.5 TOG, so it suits a low-temperature heat pump run.