Cormar Malabar Two Fold and Duralay Durafit 650: combined TOG for underfloor heating
The combined TOG for Cormar Malabar Two Fold over Duralay Durafit 650, worked against the UHMA underfloor heating rule.
Combined against the UHMA 2.5 TOG underfloor-heating limit. Under 1.5 also suits a low-temperature heat pump.
| Carpet | Cormar Malabar Two Fold (1.2 TOG) |
|---|---|
| Underlay | Duralay Durafit 650 (1.1 TOG) |
| Published sum | 2.3 TOG |
| UHMA in-situ correction | minus 1 TOG |
| Combined in-situ TOG | 1.3 TOG |
| Standard UFH limit | 2.5 TOG |
| Heat pump target | under 1.5 TOG |
Cormar Malabar Two Fold is rated 1.2 TOG and Duralay Durafit 650 is rated 1.1 TOG. Laid together the combination is what the underfloor heating has to warm through.
The published TOG figures add to 2.3. The UHMA rule subtracts 1 TOG because tests showed real in-situ resistance runs about a TOG below the paper sum, giving 1.3 TOG. That clears both the standard limit and the tighter heat-pump target.
Sources: UHMA guidance on underfloor heating with carpet and underlay (combined-TOG rule) · How to calculate a combined TOG (UHMA formula, worked) · Cormar Carpets published carpet TOG values · Interfloor / Duralay Durafit 650 underlay datasheet