Cormar Primo Textures Weave (0.9 TOG) with Cloud 9 Cirrus (2.6 TOG) gives a combined 2.5 in-situ TOG. Whether that passes the 2.5 TOG underfloor heating limit and what to do.
Updated 05 September 2026.
Cormar Primo Textures Weave and Cloud 9 Cirrus: combined TOG for underfloor heating
The combined TOG for Cormar Primo Textures Weave over Cloud 9 Cirrus, worked against the UHMA underfloor heating rule.
Combined against the UHMA 2.5 TOG underfloor-heating limit. Under 1.5 also suits a low-temperature heat pump.
| Carpet | Cormar Primo Textures Weave (0.9 TOG) |
|---|---|
| Underlay | Cloud 9 Cirrus (2.6 TOG) |
| Published sum | 3.5 TOG |
| UHMA in-situ correction | minus 1 TOG |
| Combined in-situ TOG | 2.5 TOG |
| Standard UFH limit | 2.5 TOG |
| Heat pump target | under 1.5 TOG |
Cormar Primo Textures Weave is rated 0.9 TOG and Cloud 9 Cirrus is rated 2.6 TOG. Laid together the combination is what the underfloor heating has to warm through.
The published TOG figures add to 3.5, and even after the UHMA 1 TOG in-situ correction the pair sits at 2.5 TOG, 0 TOG over the limit. The carpet is fine; the underlay is doing the damage. Keep Cormar Primo Textures Weave and drop to a low-TOG underlay such as Duralay Heatflow for Carpet (0.75 TOG) or Duralay Technics 5 (0.56 TOG), which brings the combined figure back into range.
Questions and answers
Cormar Primo Textures Weave and Cloud 9 Cirrus: combined TOG for underfloor heating?
Combined in-situ TOG is 2.5, above the 2.5 TOG limit, so Cormar Primo Textures Weave with Cloud 9 Cirrus is not suitable for underfloor heating. Keep the carpet and switch to a low-TOG underlay.