Cormar Trilogy Bronte and Duralay System Ten: combined TOG for underfloor heating
The combined TOG for Cormar Trilogy Bronte over Duralay System Ten, worked against the UHMA underfloor heating rule.
Combined against the UHMA 2.5 TOG underfloor-heating limit. Under 1.5 also suits a low-temperature heat pump.
| Carpet | Cormar Trilogy Bronte (1.4 TOG) |
|---|---|
| Underlay | Duralay System Ten (1.55 TOG) |
| Published sum | 2.95 TOG |
| UHMA in-situ correction | minus 1 TOG |
| Combined in-situ TOG | 1.95 TOG |
| Standard UFH limit | 2.5 TOG |
| Heat pump target | under 1.5 TOG |
Cormar Trilogy Bronte is rated 1.4 TOG and Duralay System Ten is rated 1.55 TOG. Laid together the combination is what the underfloor heating has to warm through.
The published TOG figures add to 2.95. The UHMA rule subtracts 1 TOG because tests showed real in-situ resistance runs about a TOG below the paper sum, giving 1.95 TOG. On a heat pump running low flow temperatures the floor has less heat to push, so aim under 1.5 TOG and prefer the thinnest underlay in this range.