Cormar Primo Ultra (1.5 TOG) with Cloud 9 Caviar & Crystal 11 (2.7 TOG) gives a combined 3.2 in-situ TOG. Whether that passes the 2.5 TOG underfloor heating limit and what to do.
Updated 05 September 2026.
Cormar Primo Ultra and Cloud 9 Caviar & Crystal 11: combined TOG for underfloor heating
The combined TOG for Cormar Primo Ultra over Cloud 9 Caviar & Crystal 11, worked against the UHMA underfloor heating rule.
Combined against the UHMA 2.5 TOG underfloor-heating limit. Under 1.5 also suits a low-temperature heat pump.
| Carpet | Cormar Primo Ultra (1.5 TOG) |
|---|---|
| Underlay | Cloud 9 Caviar & Crystal 11 (2.7 TOG) |
| Published sum | 4.2 TOG |
| UHMA in-situ correction | minus 1 TOG |
| Combined in-situ TOG | 3.2 TOG |
| Standard UFH limit | 2.5 TOG |
| Heat pump target | under 1.5 TOG |
Cormar Primo Ultra is rated 1.5 TOG and Cloud 9 Caviar & Crystal 11 is rated 2.7 TOG. Laid together the combination is what the underfloor heating has to warm through.
The published TOG figures add to 4.2, and even after the UHMA 1 TOG in-situ correction the pair sits at 3.2 TOG, 0.7 TOG over the limit. The carpet is fine; the underlay is doing the damage. Keep Cormar Primo Ultra and drop to a low-TOG underlay such as Duralay Heatflow for Carpet (0.75 TOG) or Duralay Technics 5 (0.56 TOG), which brings the combined figure back into range.
Questions and answers
Cormar Primo Ultra and Cloud 9 Caviar & Crystal 11: combined TOG for underfloor heating?
Combined in-situ TOG is 3.2, above the 2.5 TOG limit, so Cormar Primo Ultra with Cloud 9 Caviar & Crystal 11 is not suitable for underfloor heating. Keep the carpet and switch to a low-TOG underlay.